Thermal Insulation board for Roofs. Recommended Density of Roof Foam is 32-35 kg/m³ For upside down…

PROPERTIES OF EEP E-FOAM INSULATION SYSTEM

Properties (Average) Test Standard Units Type VI Type VII
Density ASTM D-1622
DIN 53420
kg/m³
lbs/ft³
30-32
1.9-2.0
32-35
2.0-2.3
35-40
2.3-2.6
40-45
2.6-2.9
45-48
2.9-3.0
Thermal Conductivity
max @ 35° C & 60 % of RH
ASTM C 158-2010
DIN 2612/52616
W/m.K
Btu.in/ft².hr.°F
0.0301
0.2087
0.0301
0.2087
0.0301
0.2087
0.0301
0.2087
0.0301
0.2087
Thermal Resistance
of 25.4 mm Thickness @ mean temp of 24±1 °C min
ASTM C 158-2010
DIN 2612/52616
(m2.k)/W 0.88 0.88 0.88 0.88 0.88
Compressive Strength
@ Yield or 10% Deformation, min kPa
ASTM D 1621:00
DIN 53421
kPa
psi
276
40
300
44
414
60
414
60
414
60
Flexural Strength
min kPa
ASTM C 203-05a kPa
psi
414
60
414
60
517
75
517
75
517
75
Water Vapor Permeance
of 25.4 mm Thick max
ASTM E 96:00 perm/in 1.1 1.1 1.1 1.1 1.1
Water Absorption
by total immersion, max
ASTM C 272:2001
DIN 53428
% by Vol 0.3 0.3 0.3 0.3 0.3
Dimensional Stability
change in dimension , max %
ASTM D 2126:09 % change 2 2 2 2 2
Oxygen Index
min volume %
ASTM C 2863:09 % 24 24 24 24 24
Capillarity   None None None None None None
Fire Classifications DIN 4102:1 Building
Material Class
B1 & B2
Difficult to Ignite